Sign In | Join Free | My himfr.com
Home > Industrial Automation Products >

6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400

    Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers
     
    Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers
    • Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers
    • Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers
    • Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers
    • Buy cheap 6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400 from wholesalers

    6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400

    Ask Lasest Price
    Brand Name :
    Model Number : 6GK7443-1EX30-0XE0
    Certification : UL CE
    Price : consult for best discount
    Payment Terms : T/T, , Western Union,Paypal,, MoneyGram,, L/C
    Supply Ability : 50 pcs per month
    Delivery Time : 2-5 days
    • Product Details
    • Company Profile

    6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400

    CP 6GK7443-1EX30-0XE0 Communications Processor For SIMATIC S7-400 Industrial Automation Products

    Overview

    6GK7443-1EX30-0XE0 Communication Processor For SIMATIC S7 400

    Communications processor for connecting a SIMATIC S7-400 to Industrial Ethernet networks, also as PROFINET IO controller or in SIMATIC H systems.

    The CP supports:

    • PG/OP communication
    • S7 communication
    • Open communication (SEND/RECEIVE)
    • PROFINET communication
    • IT communication

    The communications processor can also be used for redundant S7 communication in SIMATIC H systems and for fail-safe applications (PROFIsafe) in connection with an S7-400 F-CPU.


    Benefits

    • High plant availability through the support of media redundancy (MRP) and use in the SIMATIC S7-400 H system
    • Optimum support of maintenance through
      • Web-based diagnostics
      • Remote programming via WAN or telephone network (ISDN)
      • Monitoring with IT network management tools (SNMP)
      • Module replacement without a PG
    • Securing the system against unauthorized access by means of:
      • Central access protection for any devices within an automation cell, e.g. by means of strong authentication of network stations
    • Investment protection thanks to later connection of existing SIMATIC S7 systems to Industrial Ethernet using the CP 443-1
    Application
    • The CP 443-1 is used to connect the SIMATIC S7-400 to Industrial Ethernet networks. With its own processor, it relieves the CPU of communications tasks and facilitates additional connections.

    The CP 443-1 offers communication options with

    • PGs/PCs
    • Host computers
    • HMI systems
    • SIMATIC S5/S7/C7 systems
    • PROFINET IO devices

    Technical data

    Product type designationCP 443-1
    Communications processor CP 443-1; 2x 10/100 Mbit/s (IE switch); RJ45 ports; ISO; TCP; UDP; PROFINET IO controller; S7 communication; Open communication (SEND/ RECEIVE); S7 routing; IP configuration via DHCP/ Block; IP Access Control List; Time synchronization; extended web diagnostics; Fast Startup; Support for PROFIenergy;
    Transmission rate
    Transfer rate
    ● at the 1st interface10 ... 100 Mbit/s
    Interfaces
    Number of interfaces / acc. to Industrial Ethernet2
    Number of electrical connections
    ● at the 1st interface / acc. to Industrial Ethernet2
    Type of electrical connection
    ● at the 1st interface / acc. to Industrial EthernetRJ45 port
    design of the removable storage / C-PLUGNo
    Supply voltage, current consumption, power loss
    Type of voltage / of the supply voltageDC
    Supply voltage / 1 / from backplane bus5 V
    Relative symmetrical tolerance / at DC
    ● at 5 V5 %
    Consumed current
    ● from backplane bus / at DC / at 5 V / typical1.4 A
    Power loss [W]7.25 W
    Permitted ambient conditions
    Ambient temperature
    ● during operation0 ... 60 °C
    ● during storage-40 ... +70 °C
    ● during transport-40 ... +70 °C
    Relative humidity / at 25 °C / without condensation / during operation / maximum95 %
    Protection class IPIP20
    Design, dimensions and weight
    Module formatCompact module S7-400 single width
    Width25 mm
    Height290 mm
    Depth210 mm
    Net weight0.7 kg
    Product properties, functions, components / general
    Number of units
    ● per CPU / maximum14
    ● Notemax. 4 as PN IO ctrl.
    Performance data / open communication
    Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum64
    Amount of data
    ● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
    ● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
    ● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
    ● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum2 Kibyte
    Number of possible connections / for open communication
    ● by means of T blocks / maximum64
    Amount of data
    ● as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum1452 byte
    Performance data / S7 communication
    Number of possible connections / for S7 communication
    ● maximum128
    ● with PG connections / maximum2
    ● Notewhen using several CPUs
    Performance data / multi-protocol mode
    Number of active connections / with multi-protocol mode128
    Performance data / PROFINET communication / as PN IO-Controller
    Product function / PROFINET IO controllerYes
    Number of PN IO devices / on PROFINET IO controller / usable / total128
    Number of PN IO IRT devices / on PROFINET IO controller / usable64
    Number of external PN IO lines / with PROFINET / per rack4
    Amount of data
    ● as user data for input variables / as PROFINET IO controller / maximum4 Kibyte
    ● as user data for input variables / as PROFINET IO controller / maximum4 Kibyte
    ● as user data for input variables per PN IO device / as PROFINET IO controller / maximum1433 byte
    ● as user data for output variables per PN IO device / as PROFINET IO controller / maximum1433 byte
    ● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 byte
    ● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 byte
    Product function / MIB supportYes
    Protocol / is supported
    ● SNMP v1Yes
    ● DCPYes
    ● LLDPYes
    Configuration software
    ● requiredSTEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher