    6ES7416-3XS07-0AB0 Simatic S7 400 , 416 CPU Central Processing Unit

    Ask Lasest Price
    Brand Name :
    Model Number : 6ES7416-3XS07-0AB0
    Certification : ROHS CE
    Price : consult for best discount
    Payment Terms : T/T, , Western Union,Paypal,, MoneyGram,, L/C
    Supply Ability : 20 Pcs/month
    Delivery Time : 2-5 days
    • Product Details
    • Company Profile

    6ES7416-3XS07-0AB0 Simatic S7 400 , 416 CPU Central Processing Unit

    SIMATIC 416 CPU 6ES7416-3XS07-0AB0 S7-400 Central Processing Unit Industrial Automation Products

    Application

    CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.

    The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.

    An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.

    The integrated PROFINET interface of the CPU 416-3 PN/DP implements switch functionality. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.

    Note:
    Only the interface module 6ES7 964-2AA04-0AB0 can be used.

    Design

    Both CPUs are equipped with the following:

    • Powerful processor:
      The CPUs achieve instruction execution times as low as 0.03 µs per binary instruction.
    • CPU 416-2: 8 MB main memory (of which 4 MB each for program and data);
      CPU 416-3: 16 MB main memory (of which 8 MB each for program and data);
      CPU 416-3 PN/DP: 16 MB main memory (of which 8 MB each for program and data);
      fast main memory for parts of the user program relevant to execution.
    • Flexible expansion:
      Up to 262144 digital and 16384 analog inputs/outputs.
    • Multi-point interface MPI:
      With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbps. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
    • Mode selector switch:
      Designed as toggle switch.
    • Diagnostics buffer:
      The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
    • Real-time clock:
      The date and time are appended to diagnostic messages of the CPU.
    • Memory card:
      For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available.
    • Combined MPI/DP interface and integrated PROFIBUS DP interface (with CPU 416‑2 and CPU 416‑3):
      The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
      Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master acc. to EN 50170.

    CPU 416-3 and CPU 416-3 PN/DP also include:

    • 1 module slot:
      Using the IF 964-DP interface module, an additional PROFIBUS DP master system can be connected.

    CPU 416-3 PN/DP additionally includes:

    • PROFINET interface with 2 ports (switch):
      • PROFINET IO, 256 IO devices connectable
      • PROFINET CBA
    Function
    • Block protection:
      A password concept protects the user program from unauthorized access.
    • Integral HMI services:
      The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
    • Integrated communications functions:
      • PG/OP communication
      • Shared data communication
      • S7 standard communication
      • S7 communication
    • Firmware update using network

    CPU 416-3 PN/DP additional:

    • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
    • Distributed intelligence in Component Based Automation (CBA) on PROFINET
    • Additional diagnostic options with integrated web server
    Parameterizable attributes

    The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

    • Multi-point interface MPI:
      • Definition of station addresses.
      • Startup/cycle behavior
      • Stipulation of the maximum cycle time and communications load
    • Address assignment:
      Addressing of I/O modules.
    • Retentive ranges:
      Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
    • Size of the process image, local data.
    • Length of the diagnostics buffer
    • Protection level:
      Definition of access authorization for program and data
    • System diagnostics:
      Definition of the handling and scope of diagnostic messages
    • Timed interrupts:
      Setting of periodicity

    Technical specifications

    Article number

    6ES7416-2XP07-0AB0

    6ES7416-3XS07-0AB0

    6ES7416-3ES07-0AB0


    CPU 416-2, MPI, PROFIBUS, 8 MB

    CPU 416-3, 16 MB, 3 INTERFACES

    CPU416-3 PN/DP, 16 MB, 3 INTERFACES

    General information
    Product type designationCPU 416-2CPU 416-3CPU 416-3 PN/DP
    HW functional status010101
    Firmware versionV7.0V7.0V7.0
    Engineering with
    • ● Programming package

    STEP 7 V5.4 or higher with HSP 261STEP 7 V5.4 or higher with HSP 261STEP 7 V5.5 or higher with HSP 262
    CiR – Configuration in RUN
    CiR synchronization time, basic load100 ms100 ms100 ms
    CiR synchronization time, time per I/O byte10 µs10 µs10 µs
    Supply voltage
    Rated value (DC)
    • ● 24 V DC

    No; Power supply via system power supplyNo; Power supply via system power supplyNo; Power supply via system power supply
    Input current
    from backplane bus 5 V DC, typ.0.9 A1.1 A1.3 A
    from backplane bus 5 V DC, max.1.1 A1.3 A1.6 A
    from backplane bus 24 V DC, max.300 mA; 150 mA per DP interface450 mA; 150 mA per DP interface300 mA; 150 mA per DP interface
    from interface 5 V DC, max.90 mA; At each DP interface90 mA; At each DP interface90 mA; At each DP interface
    Power loss
    Power loss, typ.4.5 W5.5 W6.5 W
    Power loss, max.5.5 W6.5 W8 W
    Memory
    Type of memoryRAMRAMRAM
    Work memory
    • ● integrated

    8 Mbyte16 Mbyte16 Mbyte
    • ● integrated (for program)

    4 Mbyte8 Mbyte8 Mbyte
    • ● integrated (for data)

    4 Mbyte8 Mbyte8 Mbyte
    • ● expandable

    NoNoNo
    Load memory
    • ● expandable FEPROM

    Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)Yes; with Memory Card (FLASH)
    • ● expandable FEPROM, max.

    64 Mbyte64 Mbyte64 Mbyte
    • ● integrated RAM, max.

    1 Mbyte1 Mbyte1 Mbyte
    • ● expandable RAM

    Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)Yes; with Memory Card (RAM)
    • ● expandable RAM, max.

    64 Mbyte64 Mbyte64 Mbyte
    Backup
    • ● present

    YesYesYes
    • ● with battery

    Yes; all dataYes; all dataYes; all data
    • ● without battery

    NoNoNo
    Battery
    Backup battery
    • ● Backup current, typ.

    180 µA; up to 40 °C180 µA; up to 40 °C180 µA; up to 40 °C
    • ● Backup current, max.

    850 µA850 µA850 µA
    • ● Backup time, max.

    Dealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influenceDealt with in the module data manual with the secondary conditions and the factors of influence
    • ● Feeding of external backup voltage to CPU

    5 V DC to 15 V DC5 V DC to 15 V DC5 V DC to 15 V DC
    CPU processing times
    for bit operations, typ.12.5 ns12.5 ns12.5 ns
    for word operations, typ.12.5 ns12.5 ns12.5 ns
    for fixed point arithmetic, typ.12.5 ns12.5 ns12.5 ns
    for floating point arithmetic, typ.25 ns25 ns25 ns
    CPU-blocks
    DB
    • ● Number, max.

    10 000; Number range: 1 to 1600010 000; Number range: 1 to 1600010 000; Number range: 1 to 16000
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    FB
    • ● Number, max.

    5 000; Number range: 0 to 79995 000; Number range: 0 to 79995 000; Number range: 0 to 7999
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    FC
    • ● Number, max.

    5 000; Number range: 0 to 79995 000; Number range: 0 to 79995 000; Number range: 0 to 7999
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    OB
    • ● Number, max.

    see instruction listsee instruction listsee instruction list
    • ● Size, max.

    64 kbyte64 kbyte64 kbyte
    • ● Number of free cycle OBs

    1; OB 11; OB 11; OB 1
    • ● Number of time alarm OBs

    8; OB 10-178; OB 10-178; OB 10-17
    • ● Number of delay alarm OBs

    4; OB 20-234; OB 20-234; OB 20-23
    • ● Number of cyclic interrupt OBs

    9; OB 30-38 (shortest cycle that can be set = 500 µs)9; OB 30-38 (shortest cycle that can be set = 500 µs)9; OB 30-38 (shortest cycle that can be set = 500 µs)
    • ● Number of process alarm OBs

    8; OB 40-478; OB 40-478; OB 40-47
    • ● Number of DPV1 alarm OBs

    3; OB 55-573; OB 55-573; OB 55-57
    • ● Number of isochronous mode OBs

    4; OB 61-644; OB 61-644; OB 61-64
    • ● Number of multicomputing OBs

    1; OB 601; OB 601; OB 60
    • ● Number of background OBs

    1; OB 901; OB 901; OB 90
    • ● Number of startup OBs

    3; OB 100-1023; OB 100-1023; OB 100-102
    • ● Number of asynchronous error OBs

    9; OB 80-889; OB 80-889; OB 80-88
    • ● Number of synchronous error OBs

    2; OB 121, 1222; OB 121, 1222; OB 121, 122
    Nesting depth
    • ● per priority class

    242424
    • ● additional within an error OB

    222
    Counters, timers and their retentivity
    S7 counter
    • ● Number

    2 0482 0482 048
    Retentivity
    • — adjustable

    YesYesYes
    • — lower limit

    000
    • — upper limit

    2 0472 0472 047
    • — preset

    Z 0 to Z 7Z 0 to Z 7Z 0 to Z 7
    Counting range
    • — lower limit

    000
    • — upper limit

    999999999
    IEC counter
    • ● Number

    Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)
    S7 times
    • ● Number

    2 0482 0482 048
    Retentivity
    • — adjustable

    YesYesYes
    • — lower limit

    000
    • — upper limit

    2 0472 0472 047
    • — preset

    No times retentiveNo times retentiveNo times retentive
    Time range
    • — lower limit

    10 ms10 ms10 ms
    • — upper limit

    9 990 s9 990 s9 990 s
    IEC timer
    • ● present

    YesYesYes
    • ● Type

    SFBSFBSFB
    • ● Number

    Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)Unlimited (limited only by RAM capacity)